<LOGO>
FM Transmitter Measurement Report
Created: 2025-01-03 12-33-59
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 4/5, 50 dBuV VOLTAGE
Pilot RDS Phase Difference
7.2 kHz 3.7 kHz 17 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
13 kHz 73 kHz 2839 57,3441
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
6,9 dBr 7,98 dBr 8,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 10 (Pop M) 1 0 0 5 12:33, 3.01.2025
RT
"MARTIN SOLVEIG - Rejection "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 4/5 (51 dBuV) Max at: 73 kHz MIN: 13 kHz % above 75 kHz: 57,3441 Acquired: 2025/01/03 12:32:55 Total samples: 2839 Equivalent time: 0:02:21 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200
FM Scope MAX: 8,8 dBr MIN: 6,9 dBr AVE: 7,98 dBr % above 10,0 dBr: 0,0 Last value: 8,8 dBr (2025/01/03 12:32:54) Station: 96.90 MHz, signal: 4/5 (48 dBuV) 12:26 12:27 12:28 12:29 12:30 12:31 12:32 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality